MAINTENANCE & TROUBLESHOOTING

The Warming Hut model WH2000/WH2001 in made of the highest quality component parts. We have thoroughly tested the Warming Huts at our factory before they were shipped to you. The following check list will help your installer and service persons to correct any minor problems. The Warming Hut is relatively maintenance free. General maintenance will keep your Warming Hut running properly and attractive looking.

PROBLEM / ITEMS TO CHECK

How to unlock:

  1. Insert key-push down while turning 90 degrees.
  2. Pull out entire locking assembly (about 3 inches long).
  3. Open front panel. To lock-reverse unlock instructions making sure lock is fully Seated. (Note: Leave key in lock mechanism until you complete locking).

Unit will not operate (no power):

  1. Make sure unit is plugged into (110-120V) wall outlet.
  2. Timer (Black Modular Unit) on upper right is plugged into socket.
  3. All wires are connected to blower.
  4. Check wall outlet to make sure there is power.

Unit runs when power cord in plugged into the wall outlet:

  1. Trip wire in switch under coin mechanism is stuck in down position. Trip a number of times to free.
  2. Remove timer on the inside of unit and exchange with another unit timer (if available). Test with the other timer installed.

Unit will not turn off (keeps running for more than 2 ‡ minutes).

  1. Same as #3 above.

Jammed coin or slug:

  1. Insert small wire (bent paper clip will work) into small hole located in top of unit next to coin slot and push down. This pushes lever on coin mechanism freeing the jam without opening the unit.
  2. Open unit, remove coin mechanism, follow instructions on coin mechanism to open and free jam.
No air is coming out of both black external tubes:
  1. Check the "Y" connector is pressure fitted to the blower nozzle.
  2. Check Internal hoses for holes or crimps. Make sure hose clamps are tight.

 

MAINTENANCE

  1. After 4000 uses it is recommended replacement of brushes in the motor. If brushes are not replaced when worn, blower will seize.
  2. Coin mechanism should be removed and cleaned with hot soapy water twice a year or if necessary. This will insure smooth coin operation
  3. Check Internal hoses for cracks.
  4. Keep your unit clean, do not spray any types of detergent or solvents inside the unit, wipe down inside with a clean damp towel.
  5. Provide signage for your guest (see parts list)

After reviewing this check list and you still have a problem,

please call toll free 1.888.325.9825 for assistance

back to services

For more information or
to order parts, Click Here

E-mail: warmitup.com


Pace Locker Co.

The Warming Hut
888- 325-9825
Fax 860-210-1231